Velodyne HD HDL-64E S2.1 Instrukcja Użytkownika Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 25
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
9
.
www.velodyne.com/lidar
HDL-64E S2 User’s Manual
U
se this chart to troubleshoot common problems with the HDL-64E S2.
Problem Resolution
Unit doesn’t spin Verify power connection and polarity.
Verify proper voltage – should be 12 volts
drawing about 3-4 amps.
Remove bottom cover and check inline fuse.
Replace if necessary.
Unit spins but no data Verify Ethernet wiring.
Verify packet output from another source
(e.g. Ethereal/Wireshark).
No serial communication Verify RS-232 cable connection.
Unit must be active and spinning for
RS-232 update.
It may take several tries for the update
to be ef
fective.
There are no user service or maintenance requirements or procedures for the
Velodyne HDL-64E S2.
For ser
vice or maintenance, please contact V
elodyne at (408) 465-2800, or log on to our
website at www.velodyne.com/lidar.